Product : ISaGRAF V3.05/3.4x
Date : 1-August-1996/updated 31-May-2001
File : CmpRun.Start compiler from a command line.htm
Subject : Start Compiler from a command line
Keywords: command line - compiler
____________________________________________________________________
To start the Compiler from a .bat file (on Win95 or NT)
cd \isawin\apl\rfbars
start /w \isawin\exe\wsmk1edt.exe -p=rfbars -u=B
cd \isawin\apl\rfgraph
start /w \isawin\exe\wsmk1edt.exe -p=rfgraph -u=B
example above will compile the two projects rfbars and rfgraph.
The compiling options have to be set before.
with the option -u=B the closing of the Code generator window is
done automatically, and then the new compilation starts.
If an error occurs, it will stop. In this case, if you close the
code generator window with the Files - Exit, it will then
continue on the next compilation.
To start the compiler on library elements:
WSMK1EDT.EXE -p=@libf -o=funcname
WSMK1EDT.EXE -p=@libb -o=fbname
and to avoid the message box at the end (batch mode):
WSMK1EDT.EXE -p=@libf -o=funcname -u=B
WSMK1EDT.EXE -p=@libb -o=fbname -u=B
____________________________________________________________________